RAE Systems MultiRAE Pro

From £4,282.00 (inc. VAT £5,138.40)

Make Enquiry

ShipServ

Approved Supplier

12-Month

Certified Calibration

Fast Shipping

To Ports Worldwide

Contact Us

For Custom Orders

Description

The RAE Systems MultiRAE Pro is the industry’s first wireless multi-threat detection tool that combines continuous monitoring capabilities for Gamma radiation, volatile organic compounds (VOCs) down to parts-per-billion level, toxic, combustible gases, and Oxygen, with Man Down Alarm functionality in one highly portable instrument. Certified to meet the military performance standard MIL-STD-810F, the MultiRAE Pro can be configured with 33 intelligent sensors (including ppb and ppm PID, NDIR, and exotics such as Ammonia, Chlorine, Formaldehyde, and Phosphine) to fully meet the monitoring needs of applications such as HazMat response, CBRN / TIC / TIM detection, EOD, homeland security, and civil defense.

The instrument boasts the largest display and longest battery runtime in its class (with an optional extended battery), as well as an ergonomically contoured case that is rugged, dust-tight and waterproof (IP-65 / IP-67 rating). A compartmentalised design of the MultiRAE Pro makes the replacement of its sensors, pump, and plug-and-play battery simple, even in the field, and the AutoRAE 2 Automatic Test and Calibration System ensures bump testing and calibration of up to 10 instruments is as easy as a press of a button.

When deployed on RAE Systems’ Dedicated Wireless Network, the MultiRAE provides safety officers with wireless access to real-time instrument readings and alarm status for better visibility and faster incident response. The MultiRAE five-way notification system for gas and Man Down alarms immediately alerts the user, people working in the vicinity, and safety officers at the command centre if a hazardous atmosphere has been detected or a person has been overcome.

Specifications
Size 7.6" H × 3.8" W × 2.6" D (193 × 96.5 × 66 mm)
Weight 31 oz (880 g)
Sensors Over 25 intelligent interchangeable field-replaceable sensors including gamma radiation, ppb and ppm PID sensors for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors, and CO₂ NDIR sensor
Battery Options, Runtime and Recharge Time Rechargeable Li-ion (~12-hr runtime, ~6-hr recharge time)
Extended duration Li-ion (~18-hr runtime, ~9-hr recharge time)
Alkaline adapter with 4 × AA batteries (~6-hr runtime)
Display Monochrome graphical LCD display (128 × 160) with backlighting; automatic screen “flip” feature
Display Readout Real-time reading of gas concentrations; PID measurement gas and correction factor; Man Down Alarm on/off; visual compliance indicator; battery status; datalogging on/off; wireless on/off and reception quality; STEL, TWA, peak, and minimum values
Keypad Buttons 3 operation and programming keys (Mode, Y/+, and N/-)
Sampling Built-in pump. Average flow rate: 250 cc/min. Auto shutoff in low-flow conditions
Calibration Automatic with AutoRAE 2 Test and Calibration System or manual
Alarms Wireless remote alarm notification; multi-tone audible (95 dB @ 30 cm), vibration, visible (flashing bright red LEDs), and on-screen indication of alarm conditions; Man Down Alarm with pre-alarm and real-time remote wireless notification
Datalogging Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
User-configurable datalogging intervals (from 1 to 3,600 seconds)
Communication and Data Download Data download and instrument set-up and upgrades on PC via desktop charging and PC comm. cradle, travel charger, or AutoRAE 2 Automatic Test and Calibration System
Wireless data and alarm status transmission via built-in RF modem (optional)
Wireless Network ProRAE Guardian Real-Time Wireless Safety System or EchoView Host-based Closed-Loop System
Wireless Range (Typical) MultiRAE Pro to RAELink3 [Z1] Mesh modem ~330 ft (100 m)
MultiRAE Pro to EchoView Host, RAEMesh Reader or RAEPoint ~660 ft (200 m)
MultiRAE Pro to Access Point ~330 ft (100 m)
Operating Temperature -4° to 122°F (-20° to 50°C)
Humidity 0% to 95% relative humidity (non-condensing)
Dust and Water Resistance IP-65 ingress protection rating
EMI/RFI EMC directive: 2004/108/EC
Performance Tests MIL-STD-810G and 461F compliant; E.I. CSA C22.2 No. 152; ISA-12.13.01
Languages Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
Warranty Four years on Liq O₂ sensors
Three years on CO and H₂S sensors
Two years on non-consumable components and catalytic LEL sensors
One year on all other sensors, pump, battery, and other consumable parts
Wireless Frequency ISM license-free band. IEEE 802.15.4 Sub 1GHz; Wi-Fi 802.11 b/g
Wireless Approvals FCC Part 15, CE R&TTE, Others
Radio Module Supports RM900A
Gases
Gamma 0 to 20,000 µRem/h (dose rate) 1cc CsI (Tl) scintillator with photodiode
VOC 10.6 eV (Ext. Range) 0 to 5,000 ppm 0.1 ppm
VOC 10.6 eV (PPB) 0 to 2,000 ppm 10 ppb
Catalytic LEL 0 to 100% LEL 1% LEL
NDIR (0–100% LEL Methane) 0 to 100% LEL 1% LEL
NDIR (0–100% Vol. Methane) 0 to 100% Vol. 0.1% Vol.
Carbon Dioxide (CO₂) NDIR 0 to 50,000 ppm 100 ppm
Ammonia (NH₃) 0 to 100 ppm 1 ppm
Carbon Monoxide (CO) 0 to 500 ppm 1 ppm
Carbon Monoxide (CO), Ext. Range 0 to 2,000 ppm 10 ppm
Carbon Monoxide (CO), H₂-Comp. 0 to 2,000 ppm 10 ppm
Carbon Monoxide (CO)+ 0 to 500 ppm 1 ppm
Hydrogen Sulphide (H₂S) Combo 0 to 200 ppm 0.1 ppm
Chlorine (Cl₂) 0 to 50 ppm 0.1 ppm
Chlorine Dioxide (ClO₂) 0 to 1 ppm 0.03 ppm
Ethylene Oxide (ETO-A) 0 to 100 ppm 0.5 ppm
Ethylene Oxide (ETO-B) 0 to 10 ppm 0.1 ppm
Formaldehyde (HCHO) 0 to 10 ppm 0.05 ppm
Hydrogen Cyanide (HCN) 0 to 50 ppm 0.5 ppm
Hydrogen Sulphide (H₂S) 0 to 100 ppm 0.1 ppm
Methyl Mercaptan (CH₃-SH) 0 to 10 ppm 0.1 ppm
Nitric Oxide (NO) 0 to 250 ppm 0.5 ppm
Nitrogen Dioxide (NO₂) 0 to 20 ppm 0.1 ppm
Oxygen (O₂) 0 to 30% Vol. 0.1% Vol.
Oxygen (LiQ O₂) 0 to 30% Vol. 0.1% Vol.
Phosphine (PH₃) 0 to 20 ppm 0.1 ppm
Phosphine (PH₃-H) 0 to 20 ppm 0.1 ppm
Sulphur Dioxide (SO₂) 0 to 20 ppm 0.1 ppm
Approvals
CSA Class I, Division 1, Groups A, B, C and D, T4; Class II, Division 1, Groups E, F, G, T85°C
ATEX 0575 II 1G Ex ia IIC T4 Ga; 2G Ex ia d IIC T4 Gb with IR sensor installed; 1M1 Ex ia I Ma
IECEx Ex ia IIC T4 Ga; Ex ia d IIC T4 Gb with IR sensor installed; 1M1 Ex ia I Ma
IECEx / ANZEx Ex ia IIC T4 Ga; Ex ia d IIC T4 Gb with IR sensor installed; Ex ia I Ma
Documentation

The RAE Systems MultiRAE Pro is the industry’s first wireless multi-threat detection tool that combines continuous monitoring capabilities for Gamma radiation, volatile organic compounds (VOCs) down to parts-per-billion level, toxic, combustible gases, and Oxygen, with Man Down Alarm functionality in one highly portable instrument. Certified to meet the military performance standard MIL-STD-810F, the MultiRAE Pro can be configured with 33 intelligent sensors (including ppb and ppm PID, NDIR, and exotics such as Ammonia, Chlorine, Formaldehyde, and Phosphine) to fully meet the monitoring needs of applications such as HazMat response, CBRN / TIC / TIM detection, EOD, homeland security, and civil defense.

The instrument boasts the largest display and longest battery runtime in its class (with an optional extended battery), as well as an ergonomically contoured case that is rugged, dust-tight and waterproof (IP-65 / IP-67 rating). A compartmentalised design of the MultiRAE Pro makes the replacement of its sensors, pump, and plug-and-play battery simple, even in the field, and the AutoRAE 2 Automatic Test and Calibration System ensures bump testing and calibration of up to 10 instruments is as easy as a press of a button.

When deployed on RAE Systems’ Dedicated Wireless Network, the MultiRAE provides safety officers with wireless access to real-time instrument readings and alarm status for better visibility and faster incident response. The MultiRAE five-way notification system for gas and Man Down alarms immediately alerts the user, people working in the vicinity, and safety officers at the command centre if a hazardous atmosphere has been detected or a person has been overcome.

Size 7.6" H × 3.8" W × 2.6" D (193 × 96.5 × 66 mm)
Weight 31 oz (880 g)
Sensors Over 25 intelligent interchangeable field-replaceable sensors including gamma radiation, ppb and ppm PID sensors for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors, and CO₂ NDIR sensor
Battery Options, Runtime and Recharge Time Rechargeable Li-ion (~12-hr runtime, ~6-hr recharge time)
Extended duration Li-ion (~18-hr runtime, ~9-hr recharge time)
Alkaline adapter with 4 × AA batteries (~6-hr runtime)
Display Monochrome graphical LCD display (128 × 160) with backlighting; automatic screen “flip” feature
Display Readout Real-time reading of gas concentrations; PID measurement gas and correction factor; Man Down Alarm on/off; visual compliance indicator; battery status; datalogging on/off; wireless on/off and reception quality; STEL, TWA, peak, and minimum values
Keypad Buttons 3 operation and programming keys (Mode, Y/+, and N/-)
Sampling Built-in pump. Average flow rate: 250 cc/min. Auto shutoff in low-flow conditions
Calibration Automatic with AutoRAE 2 Test and Calibration System or manual
Alarms Wireless remote alarm notification; multi-tone audible (95 dB @ 30 cm), vibration, visible (flashing bright red LEDs), and on-screen indication of alarm conditions; Man Down Alarm with pre-alarm and real-time remote wireless notification
Datalogging Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
User-configurable datalogging intervals (from 1 to 3,600 seconds)
Communication and Data Download Data download and instrument set-up and upgrades on PC via desktop charging and PC comm. cradle, travel charger, or AutoRAE 2 Automatic Test and Calibration System
Wireless data and alarm status transmission via built-in RF modem (optional)
Wireless Network ProRAE Guardian Real-Time Wireless Safety System or EchoView Host-based Closed-Loop System
Wireless Range (Typical) MultiRAE Pro to RAELink3 [Z1] Mesh modem ~330 ft (100 m)
MultiRAE Pro to EchoView Host, RAEMesh Reader or RAEPoint ~660 ft (200 m)
MultiRAE Pro to Access Point ~330 ft (100 m)
Operating Temperature -4° to 122°F (-20° to 50°C)
Humidity 0% to 95% relative humidity (non-condensing)
Dust and Water Resistance IP-65 ingress protection rating
EMI/RFI EMC directive: 2004/108/EC
Performance Tests MIL-STD-810G and 461F compliant; E.I. CSA C22.2 No. 152; ISA-12.13.01
Languages Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
Warranty Four years on Liq O₂ sensors
Three years on CO and H₂S sensors
Two years on non-consumable components and catalytic LEL sensors
One year on all other sensors, pump, battery, and other consumable parts
Wireless Frequency ISM license-free band. IEEE 802.15.4 Sub 1GHz; Wi-Fi 802.11 b/g
Wireless Approvals FCC Part 15, CE R&TTE, Others
Radio Module Supports RM900A
Gamma 0 to 20,000 µRem/h (dose rate) 1cc CsI (Tl) scintillator with photodiode
VOC 10.6 eV (Ext. Range) 0 to 5,000 ppm 0.1 ppm
VOC 10.6 eV (PPB) 0 to 2,000 ppm 10 ppb
Catalytic LEL 0 to 100% LEL 1% LEL
NDIR (0–100% LEL Methane) 0 to 100% LEL 1% LEL
NDIR (0–100% Vol. Methane) 0 to 100% Vol. 0.1% Vol.
Carbon Dioxide (CO₂) NDIR 0 to 50,000 ppm 100 ppm
Ammonia (NH₃) 0 to 100 ppm 1 ppm
Carbon Monoxide (CO) 0 to 500 ppm 1 ppm
Carbon Monoxide (CO), Ext. Range 0 to 2,000 ppm 10 ppm
Carbon Monoxide (CO), H₂-Comp. 0 to 2,000 ppm 10 ppm
Carbon Monoxide (CO)+ 0 to 500 ppm 1 ppm
Hydrogen Sulphide (H₂S) Combo 0 to 200 ppm 0.1 ppm
Chlorine (Cl₂) 0 to 50 ppm 0.1 ppm
Chlorine Dioxide (ClO₂) 0 to 1 ppm 0.03 ppm
Ethylene Oxide (ETO-A) 0 to 100 ppm 0.5 ppm
Ethylene Oxide (ETO-B) 0 to 10 ppm 0.1 ppm
Formaldehyde (HCHO) 0 to 10 ppm 0.05 ppm
Hydrogen Cyanide (HCN) 0 to 50 ppm 0.5 ppm
Hydrogen Sulphide (H₂S) 0 to 100 ppm 0.1 ppm
Methyl Mercaptan (CH₃-SH) 0 to 10 ppm 0.1 ppm
Nitric Oxide (NO) 0 to 250 ppm 0.5 ppm
Nitrogen Dioxide (NO₂) 0 to 20 ppm 0.1 ppm
Oxygen (O₂) 0 to 30% Vol. 0.1% Vol.
Oxygen (LiQ O₂) 0 to 30% Vol. 0.1% Vol.
Phosphine (PH₃) 0 to 20 ppm 0.1 ppm
Phosphine (PH₃-H) 0 to 20 ppm 0.1 ppm
Sulphur Dioxide (SO₂) 0 to 20 ppm 0.1 ppm
CSA Class I, Division 1, Groups A, B, C and D, T4; Class II, Division 1, Groups E, F, G, T85°C
ATEX 0575 II 1G Ex ia IIC T4 Ga; 2G Ex ia d IIC T4 Gb with IR sensor installed; 1M1 Ex ia I Ma
IECEx Ex ia IIC T4 Ga; Ex ia d IIC T4 Gb with IR sensor installed; 1M1 Ex ia I Ma
IECEx / ANZEx Ex ia IIC T4 Ga; Ex ia d IIC T4 Gb with IR sensor installed; Ex ia I Ma