Make Enquiry
Sales - mark@ribble-enviro.co.uk
Offer applicable only to portable gas detectors bought directly from our website.
Climax 731-C
From £28.03 (inc. VAT £33.64)
Dräger X-Plore 8500 PAPR Unit
Dräger X-Plore 8700 (EX) PAPR Unit
YSI Pro Plus Quatro
From £190.00 p/week (inc. VAT £228.00)
Dräger Alcotest® 7510
From £1,678.40 (inc. VAT £2,014.08)
MSA Evolution E6000 TIC
From £6,907.30 (inc. VAT £8,288.76)
Dräger Interlock® 7000
Honeywell BW MicroClip X3 is a compact four-gas personal detector for harsh industrial and confined-space environments with extended operating life.
The Honeywell BW MicroClip X3 is a personal multi-gas detector for everyday use in industrial plants and confined spaces. It simultaneously monitors up to four gases, combining long-life sensing, rugged construction and clear multi-mode alarms in a compact, clip-on format. With an extended operating life, minimal routine intervention and simple one-button operation, it supports cost-effective fleet deployment while helping safety teams maintain consistent gas monitoring standards across diverse sites and workforces.
For detailed technical data, consult the Specifications tab.
The Honeywell BW MicroClip X3 is designed for organisations that require reliable multi-gas protection without frequent detector turnover. Its industry-leading five-year operating life extends the replacement cycle, while a three-year warranty on electronics, battery and sensors supports predictable budgeting. An all-new oxygen sensor is engineered to last for the life of the detector, removing routine O2 sensor change-outs, reducing spare parts holdings and avoiding associated downtime. This combination of long-life components and warranty coverage makes the MicroClip X3 well suited to larger fleets and cost-sensitive safety programmes.
The detector simultaneously measures oxygen, combustibles, hydrogen sulphide and carbon monoxide, providing continuous coverage against common atmospheric hazards in process plants, utilities, wastewater facilities and confined spaces. High sensor resolution down to 1 ppm for CO and H2S, and fine O2 resolution, supports accurate exposure assessment and more informed decisions in the field. Real-time concentration readings on a clear LCD display allow workers and supervisors to see changing conditions, rather than relying solely on alarm states. Typical alarm setpoints for low, high, time-weighted average, short-term exposure and over-limit conditions help support comprehensive exposure control strategies aligned with site policies.
The Honeywell BW MicroClip X3 is engineered to maintain performance across a wide operating temperature and humidity range, enabling deployment in varied climates and indoor or outdoor applications. It is guaranteed to run for at least a full 12-hour shift even at -20 °C, while maintaining combustible gas detection, which is particularly valuable for cold-climate operations and outdoor maintenance activities. In typical temperatures, the lithium-polymer rechargeable battery delivers around 18 hours of runtime and recharges in less than six hours, helping teams support shift patterns and reduce charging bottlenecks.
A robust, impact-resistant, concussion-proof housing withstands daily knocks, while the high-visibility yellow finish makes the detector easier to locate on clothing or personal protective equipment and during emergency musters. IP68 ingress protection, including immersion resistance, allows reliable operation in wet, dusty or splash-prone areas. Approvals covering hazardous locations and global markets support use in regulated industries and across multi-site operations.
The compact, ergonomic form factor, approximate dimensions of a small handheld device and low weight make the MicroClip X3 comfortable for extended wear. An integrated clip allows easy attachment to belts, pockets or harnesses for hands-free monitoring, supporting consistent use throughout the shift. Audible, visual and vibrating alarms, with noise-level-rated output suited to typical industrial sound environments, help ensure that warnings are recognised even where visibility or noise levels are challenging. The high-visibility housing further assists supervisors in confirming detector presence and active use in the field.
A single-button interface and intuitive LCD icons keep operation straightforward, reducing training time, limiting scope for incorrect use and helping deter unauthorised adjustments. On-board language options, including English, French, German, Spanish and Portuguese, support mixed-language workforces and multi-country deployments.
The IntelliFlashâ„¢ compliance light provides a clear, flashing green indicator that the detector is operating and in compliance, allowing quick visual checks rather than time-consuming manual inspections. An optional confidence beep can be enabled to reassure users that the instrument is on and functioning. Continuous self-tests of sensors, battery and circuitry, combined with Reflexâ„¢ Technology to verify sensor responsiveness, help maintain instrument readiness between scheduled service intervals and support a strong safety margin.
The MicroClip X3 offers configurable options so that safety managers can align operation with site procedures. Combustible gas readings can be displayed in % LEL or % volume methane, and the IntelliFlashâ„¢ interval and confidence beep can be adjusted. Calibration gas levels are user-settable, and the detector can be configured to force calibration when overdue, supporting internal quality and compliance requirements. Options for low alarm acknowledge and custom start-up messages allow further tailoring to local safety rules and permit-to-work processes.
Integrated datalogging captures at least 16 hours of exposure data at 15-second intervals. These records assist with incident investigations, regulatory audits and longer-term exposure tracking, providing objective evidence to support risk assessments and improvement plans in areas where explosive or toxic gases may be present.
For teams managing multiple detectors, the Honeywell BW MicroClip X3 fits into a wider Honeywell ecosystem. Compatibility with Honeywell SafetySuite software supports centralised device configuration, status monitoring and reporting across sites, while integration with Honeywell BW Connect and BLE wireless technology enables real-time remote visibility of worker exposure and detector status where deployed. IntelliDox docking stations automate bump testing, calibration and data transfer, helping reduce manual record-keeping and the risk of administrative errors.
Battery and sensors are optimised to minimise maintenance downtime, and the detector can be supplied with charger and calibration certificate, with the option for laboratory calibration prior to dispatch. Access to professional maintenance and calibration services via authorised Honeywell BW service centres further supports organisations that prefer structured, outsourced service arrangements, allowing the MicroClip X3 to function as a practical, long-term platform for personal multi-gas protection.
| Size | 11.3 × 6.0 × 3.2 cm / 4.4 × 2.4 × 1.2 in. |
| Weight | 179 g / 6.3 oz. |
| Temperature | -20 to +50°C / -4 to +122°F |
| Humidity | 0% - 95% RH (non-condensing) |
| Alarms | Visual, vibrating, audible (95 dB) • Low, High, TWA, STEL, OL (over limit) |
| Tests | Audible/visual alarms on activation; sensors, battery and circuitry (continuous) |
| Typical Battery Life | 18 hours; recharges in less than 6 hours Note: Approximately 20% capacity loss is normal with lithium polymer batteries after 500 charge cycles. Refer to the Operator's Manual for additional information. |
| User Options | Confidence beep Set STEL interval Sensor on/off Latching alarms Safe display mode Stealth mode Calibration lock Auto zero on start up O2 auto calibration on start up Set bump test interval Force bump test when overdue IntelliFlashâ„¢ interval Combustible gas measurement (%LEL or % by volume methane) User-settable calibration gas level Force calibration when overdue Low alarm acknowledge Language choices Set custom start up message |
| Ratings | IP68 – up to 45 minutes at 1.2 m EMI/RFI: Complies with EMC Directive 2004/108/EC |
| Certifications and Approvals | CSA: Class I, Div. 1, Gr. A, B, C, D |
| ATEX: II 1 G. Ex ia IIC T4 Ga | |
| IECEx: Ex ia IIC T4 Ga | |
| CE: European Conformity | |
| KTL: Certification in progress | |
| Warranty | Full three-year warranty including all sensors Note: Battery is guaranteed to have 12 hour runtime during warranty period under normal operating temperature of 4°F / -20°C to 122°F / 50°C. |
| Expected Service Lifetime | Five years including all sensors* *Note: Sensors do not contain consumable components and will typically reach the expected lifetime if used according to the instructions in the user manual. Please note that poisoned sensors are not covered by warranty. |
| Gas | Measuring Range | Resolution |
| Hydrogen Sulphide (H2S) | 0 - 100 ppm | 1 ppm |
| Carbon Monoxide (CO) | 0 - 500 ppm | 1 ppm |
| Oxygen (O2) | 0 - 30.0% | 0.1% |
| Combustible Gases | 0 - 100% LEL 0 - 5.0% v/v |
1% 0.1% |
Alarm setpoints for all sensors are user adjustable. Setpoints are automatically displayed during instrument start up.
Due to ongoing research and product improvement, specifications are subject to change without notice.
| MCX3-XWHM-Y-UK | BW MicroClip X3 |
| PRODUCT | Price | Buy |
|---|---|---|
| £25.00 | ||
| £338.00 |
| PRODUCT | Price | Buy |
|---|---|---|
| £39.00 | ||
| £39.00 | ||
| £42.00 | ||
| £39.00 | ||
| £24.00 | ||
| £106.00 | ||
| £21.00 | ||
| £17.00 | ||
| £64.00 | ||
| £10.00 | ||
| £352.00 |
No account yet?
Create an Account