Drager XAM 2500

Sale!£934.00 £340.00ex. VAT £408.00 inc. VAT

We are the UK leader in Gas Detection and we’re here to help. Call us on 01200 445 804 or email info@ribble-enviro.co.uk

The Dräger X-am 2500® was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2, CO, NO2, SO2 and H2S. Reliable and fully mature measuring technology, durable sensors and easy handling guarantee a high degree of safety with extremely low operating costs.

*** Currently a 12-16 Week Delay in delivery ***

Monitor Details *

Accessories

Replacement Sensors

Regulator

Regulator must be purchased separately from gas if one is required

Calibration Gas

We are the UK leader in Gas Detection and we’re here to help. Call us on 01200 445 804 or email info@ribble-enviro.co.uk

Durable electrochemical sensors

Fully developed, high performance Dräger sensors in an extra small format for CO, H2S, O2, SO2 and NO2 gases enable safe use in industry, mining and in refineries. The impressive hydrogen sulphide sensor has a high resolution, so it can reliably measure even very low workplace limits. The non-consumptive and lead-free sensor for oxygen is characterized by an especially long service life of more than 5 years. Our CO and H2S sensors also have this long service life expectation, so they contribute to especially low operating costs.

Maximum safety

The Dräger X-am 2500 has Ex approval for zone 0, so it is clearly designed for very high user safety in areas subject to explosion hazard. The functional design ensures that gas can enter from above and from the side – even if the instrument is inside a pocket or if the front gas entry is accidentally covered.

Diffusion or pump

For clearance measurements for tanks and shafts or when searching for leaks, an optional external pump with a hose up to 30 m long is the optimum solution. When the measuring instrument is inserted, the pump function starts automatically. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.

Reliable power supply

The Dräger X-am 2500 can operate with either alkaline batteries or with rechargeable NiMH batteries. This enables a reliable power supply for more than 12 hours, and with the high capacity battery pack more than 13 hours. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without Ex sensor is typically more than 250 hours.

Poison resistant ex sensor

The innovative, catalytic Ex sensor is impressive due to its high resistance to silicone and hydrogen sulphide. Together with the high degree of drift stability, this resistance enables an extraordinarily long service life of more than 4 years. Its high sensitivity with regard to flammable gases and vapours is confirmed by technical approval for measuring according to IEC/EN 60079-29-1 from methane to nonane. This approval also demonstrates the suitability of this instrument for use in refineries and in the chemical industry as well.

Maintenance: fast, easy, inexpensive

From functional test to complete documentation, users have access to practical solutions that provide safety for implementation at any time. The Dräger Bump Test Station, which does not require a local power source, and the automatic Dräger X-dock testing and calibration station for comprehensive equipment management are ideal system additions that save time and effort. Together with the Dräger X-dock, the high quality Dräger sensors enable quick bump tests of 8 to 15 seconds1 with very low gas consumption. This significantly reduces your equipment operating costs.

1) With standard sensors: CH4, O2, CO, H2S

Ergonomic and robust

Thanks to its low weight and ergonomic design, the Dräger X-am 2500 offers a high degree of wearing comfort. The practical two button control panel and easy menu navigation allow the instrument to be used intuitively, despite its comprehensive functionality. The integrated protective rubber coating and sensors that are not sensitive to shock provide additional safety in case of impacts or vibrations. Moreover, the Dräger X-am 2500 is not sensitive to electromagnetic radiation, e.g. from wireless devices. The Dräger X-am 2500 is water and dust resistant in accordance with protection class IP 67, so full functionality is guaranteed even if it falls into the water.

Reviews

There are no reviews yet.

Be the first to review “Drager XAM 2500”

Your email address will not be published. Required fields are marked *

Brand

Drager

Our Customer's Thoughts

NEWS

Dangers of Flammable Gases

Flammable gases pose significant dangers due to their ability to ignite and sustain combustion. Here are some of the key hazards associated with flammable gases: Fire and Explosion: Flammable gases can ignite easily in the presence of an ignition source such as a spark, flame, or heat. Once ignited, they can rapidly propagate combustion, leading to fires and explosions. These ...

Volatile Organic Compounds ( VOC’s )

Volatile Organic Compounds (VOCs) are a group of chemicals that can easily evaporate into the air at room temperature. They are emitted from a wide array of sources, including household products, building materials, and industrial processes. While many VOCs are harmless, some can pose significant health risks, especially when present in high concentrations or in poorly ventilated spaces. Here are ...

Dangers of Hydrogen Sulphide Gas

Another common hazard we are asked about is dangers from slurry on farms and how H2S can easily overpower anyone who gets too near . Hydrogen sulfide (H2S) gas poses several dangers to human health and the environment. Here are some of the main risks associated with exposure to hydrogen sulfide: Toxicity: Hydrogen sulfide is highly toxic even at low ...

Got a Question?

Our specialist gas safety team are on hand to answer any of

your queries.

 

Contact us today for advice or assistance.