GC310 ATEX Certified 4 Gas Confined Space Monitor

Sale!£350.00 £250.00ex. VAT £300.00 inc. VAT

We are the UK leader in Gas Detection and we’re here to help. Call us on 01200 445 804 or email info@ribble-enviro.co.uk

Range:

  • H2S:01-100ppm
  • CO: 0-1000ppm
  • O2: 0-30%VOL
  • Combustible gas(CH4): 0-100%LEL

Calibration: Automatical calibration and zero

Sensor: Catalytic combustion type, electrochemical sensor (with temperature compensation), PID sensor

Responding: T90 < 30s

Alarms: Flashing wide-angled LED alarm light LCD reading; 90dB impulse output

Display: LCD display of gas reading and condition, display TWA and peak value when needed

Ambient Environment: -20-50C, 5-90%RH (no condensation)

Power Supply: 3.6V Li-ion chargeable battery can work 200 hours

Enclosure: compact, durable ruggedised ABS shell

Size & Weight: 126x66x32 (mm), 220g

Explosion Grade: EX ib II CT3

Monitor Details

We are the UK leader in Gas Detection and we’re here to help. Call us on 01200 445 804 or email info@ribble-enviro.co.uk

Features:

Range:

  • H2S:01-100ppm
  • CO: 0-1000ppm
  • O2: 0-30%VOL
  • Combustible gas(CH4): 0-100%LEL

Calibration: Automatical calibration and zero

Sensor: Catalytic combustion type, electrochemical sensor (with temperature compensation), PID sensor

Responding: T90 < 30s

Alarms: Flashing wide-angled LED alarm light LCD reading; 90dB impulse output

Display: LCD display of gas reading and condition, display TWA and peak value when needed

Ambient Environment: -20-50C, 5-90%RH (no condensation)

Power Supply: 3.6V Li-ion chargeable battery can work 200 hours

Enclosure: compact, durable ruggedised ABS shell

Size & Weight: 126x66x32 (mm), 220g

Explosion Grade: EX ib II CT3

Reviews

There are no reviews yet.

Be the first to review “GC310 ATEX Certified 4 Gas Confined Space Monitor”

Your email address will not be published. Required fields are marked *

Brand

Our Customer's Thoughts

NEWS

Dangers of Flammable Gases

Flammable gases pose significant dangers due to their ability to ignite and sustain combustion. Here are some of the key hazards associated with flammable gases: Fire and Explosion: Flammable gases can ignite easily in the presence of an ignition source such as a spark, flame, or heat. Once ignited, they can rapidly propagate combustion, leading to fires and explosions. These ...

Volatile Organic Compounds ( VOC’s )

Volatile Organic Compounds (VOCs) are a group of chemicals that can easily evaporate into the air at room temperature. They are emitted from a wide array of sources, including household products, building materials, and industrial processes. While many VOCs are harmless, some can pose significant health risks, especially when present in high concentrations or in poorly ventilated spaces. Here are ...

Dangers of Hydrogen Sulphide Gas

Another common hazard we are asked about is dangers from slurry on farms and how H2S can easily overpower anyone who gets too near . Hydrogen sulfide (H2S) gas poses several dangers to human health and the environment. Here are some of the main risks associated with exposure to hydrogen sulfide: Toxicity: Hydrogen sulfide is highly toxic even at low ...

Got a Question?

Our specialist gas safety team are on hand to answer any of

your queries.

 

Contact us today for advice or assistance.